Mitsubishi — 3.11.1 Configuration

Chapter 3 Creating and Editing Screens 3-228 Revision May, 2010 General tab in Configuration option Upload/Download The user can select USB or PC communication port (i.e. RS-232) or Ethernet to upload and download. Startup Delay Time Use to set delay time for waiting the startup of external controller (i.e. PLC). The range is between 0 ~ 255 seconds. Clock Macro Delay Time Use to set interval time when executing clock macro. The range is 100 – 65535 ms. Clock Macro Priority Used to set the priority when executing clock macro. Setting this option can ensure the more correct clock macro delay time.

Background macro update cycle Used to set the executing lines when executing background macro for one cycle. The range is 1~512 lines. Show disk access error message When this option is set, if an error occurred when accessing the alarm, history buffer, and recipe data via USB disk, an error message will show up on the screen to alert the user. Control Block tab in Configuration option Control Address Use to set the starting address of system control block. Length The length of control block will be different depending on different function.

(For example, the length should be at least 8 Words when using multi-language function.) For more detailed information of system control block, refer to section 3.4. Please note that the when the control block size is set to 0, the control block function is disabled.