Hantek — DPO7000 UserManual

To Trigger the Oscilloscope EN 1. Type: Click on the Type menu label and select "LIN trigger" to set the LIN trigger. After selecting the trigger type, the current trigger setting information, including trigger type, trigger source, and trigger level, will be displayed at the top of the screen, and will change with the change of the trigger setting. 2. Source: Click on the Source menu tab and select CH1-CH4 or EXT as the specified source. Only by selecting the channel that has been connected to the signal as the trigger source can stable triggering be obtained. 3. When: Click on the When menu tab to select the desired trigger condition. ⚫ Interval Field:

Triggered by the edge after the end of LIN interval. ⚫ Sync Field: Triggered upon completion of LIN sync field data reception. ⚫ ID Field: triggered after receiving data from LINID field. ⚫ Sync Code Error: Triggered when the LIN synchronization field data reception is completed but the synchronization field data is not equal to 0x55. ⚫ Identifier: Triggered when the LINID field data is received and the ID data is equal to the user set ID. ⚫ ID And Data: LIN data is received normally, and both ID and data are triggered by the user's set data. 4. Baud: DPO7000 User manua l Copyright © Qingdao Hantek Electronic Co., LTD 84