To Set the Vertical System EN 5.4 Channel Coupling Setting the coupling method can filter out unwanted signals. Open the vertical menu of the channel and click on the Coupling menu to select the coupling method. As shown in the following figure. ⚫ When the coupling method is "DC": both the DC and AC components contained in the measured signal can pass through. ⚫ When the coupling method is "AC": the DC component contained in the measured signal is blocked. ⚫ When the coupling method is "GND": both the DC and AC components contained in the measured signal are blocked. After setting the coupling method, the current coupling method will be displayed at the channel label. Tip:
When the input impedance is selected as 50 ohms, the coupling mode of the channel can only be set to DC and cannot be changed. 5.5 Bandwidth Limit This oscilloscope supports bandwidth limiting function. Setting bandwidth limits can reduce noise in the displayed waveform. ⚫ When the bandwidth limit is turned off, the high-frequency components contained in the measured signal can pass through. ⚫ If the bandwidth limit is turned on and limited to 20MHz, the high-frequency components greater than 20MHz contained in the measured signal will be Copyright © Qingdao Hantek Electronic Co., LTD DPO7000 User manual 35