Hantek — DPO7000 UserManual

To Trigger the Oscilloscope EN 1. Type: Click on the Type menu label and select "Overtime" to set the trigger. After selecting the trigger type, the current trigger setting information (including trigger type, trigger source, and trigger level) will be displayed at the top of the screen, which changes with the trigger setting. 2. Source: Click on the Source menu tab to select sources such as CH1, CH2, CH3, CH4, and EXT. 3. Slope type: Click on the Slope Type menu tab to select rising and falling edges. ⚫ Rising: Start timing by triggering the level on the rising edge of the input signal. ⚫ Falling: Start timing by triggering the level at the falling edge of the input signal. 4. Timeout:

Click on the Timeout time menu tab, and set the trigger release by selecting the multi-functional knob V0 or the pop-up numeric keyboard to directly set it. 8.6.6 Window Trigger Window triggering provides high and low trigger levels. When the input signal passes the high or low trigger level, the oscilloscope triggers. DPO7000 User manua l Copyright © Qingdao Hantek Electronic Co., LTD 70