Hantek — DPO7000 UserManual

To Trigger the Oscilloscope EN 1. Type: Click on the Type menu label and select " Pattern Trigger" to set the Pattern trigger. After selecting the trigger type, the current trigger setting information (including trigger type, trigger source, and trigger level) will be displayed at the top of the screen, which changes with the trigger setting. 2. Source: Click on the Source menu tab and select CH1-CH4. Only by selecting the channel that has been connected to the signal as the trigger source can stable triggering be obtained. 3. Code: Click on the Code menu tab and select: H, L, X, Rising, Falling, or Either. 4. Logic type: Click on the Logic type menu tab to select: OR, AND. 5. Holdoff:

Please refer to the introduction in the section on Trigger Holdoff for specific settings related to Holdoff. 8.6.10 Delay Trigger Delay triggering requires setting source A and source B separately. When the time difference ( △ T) between the edge set by source A (edge A) and the edge set by source Copyright © Qingdao Hantek Electronic Co., LTD DPO7000 User manual 77