DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming M1534: Enable ramp-down time setting on Y0. Has to be used with D1348 M1535: Enable ramp-down time setting on Y2. Has to be used with D1349 2. Description on associated special registers: For D1030~D1033, D1336~D1339, D1220, D1221, please refer to PLSY instruction D1026: M1156 = ON, D1026 stores pulse number for masking Y0 (Low word). D1027: M1156 = ON, D1026 stores pulse number for masking Y0 (High word). D1135: M1158 = ON, D1135 stores pulse number for masking Y2 (Low word). D1136: M1158 = ON, D1135 stores pulse number for masking Y2 (High word). D1348: M1534 = ON, D1348 stores the ramp-down time of CH0(Y0, Y1) pulse output.
D1349: M1535 = ON, D1349 stores the ramp-down time of CH1(Y2, Y3) pulse output. D1340 Start/end frequency of the pulse output CH0 (Y0, Y1) D1352 Start/end frequency of the pulse output CH1 (Y2, Y3) 3. Operation of Mark function on Y0: Frequency Target speed X4 external interrupt Start/end freuquency D1340 Pulse number if no external interrupt on X4 Ramp-down time Time Ramp-up time D1348 Pulse number DD1232 Ramp-down stop pulse number when Mark is detected When M1156/M1158 = ON, enable ramp-down pause (Mark function) on Y0/Y2 when X4/X6 receives interrupt signals. 3-150 Y2. D1232: Output pulse number for ramp-down stop when Y0 mark sensor receives signals. (Low word). D1233:
Output pulse number for ramp-down stop when Y0 mark sensor receives signals. (High word). D1234: Output pulse number for ramp-down stop when Y2 mark sensor receives signals (Low word). D1235: Output pulse number for ramp-down stop when Y2 mark sensor receives signals (High word).