DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming Frequency Y0 is masked from interrupts on X4 Y0 is ready for interrupts from X4 Target speed Pulse number if no external interrupt on X4 Start/end frequency Time D1340 Pulse number Pulses to be masked, Ramp down time (D1348) Specified by DD1026 Ramp-down stop pulse number when Mark is detected (D ) D1232 Mask function on Y0 will be enabled when D1026 and D1027 are specified with values other than 0. Mask function is disabled when D1026 and D1027 are specified with 0. If pulse output process can not reach the target speed, PLC will clear DD1026 to disable the Mask function.
If the Mask range is set to be within the ramp-up section, PLC will automatically modify DD1026 to be longer than the ramp-up section. On the other hand, if DD1026 is set between ramp- down section, PLC will modify DD1026 to be the range before the beginning of ramp-down process. Mask function setting method on Y2 is the same as Y0. Program example 2: Y0 I401 Explanations: When M0 is triggered, Y0 executes pulse output. When external interrupt is detected on X4 after 50,000 pulses, pulse output will perform ramp down process for 10,000 pulses and then stop. M1108 will be ON. If no interrupt is detected on X4, Y0 pulse output will stop after 1,000,000 pulses are completed.