Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

3. Instruction Set performed before 50,000 pulses are achieved. Points to note:  When Mark function is executed with Mask function, PLC will check the validity of Mask range first, then ramp-down stop pulses of Mark function. If the above set values exceed the proper range, PLC will automatically modify the set values after the instruction is executed.  When PLSR or positioning instructions with ramp-up/down section are enabled, the user can check the pulses of ramp-up section in DD1127 and pulses of ramp-down section in DD1133.  Users can perform single speed positioning when ramp-up/down time setting is not specified. 5.

Adding mask and alignment mark function for CH0 and CH1  Available for the followings  CH0 and CH1 relative parameters for Mask and Alignment Mark function: 3-153 ES2/ 12SA2/ Series ES2-C ES2-E SS2 12SE 26SE 28SA2 EX2 SX2 Firmware V3.28 V3.28 V1.00 V2.82 V3.28 -- V2.0 V3.0 version Output number Marking deceleration flag External input point Ramp-up time Ramp-down time Starting/ Stopping frequency Number of Front masking Back masking ramp-down pulses after marking CH0 (Y0/Y1) M1156 X4 D1343 D1348 D1340 D1232/D12 33 D1026 D1027 D1100 D1101 CH1 (Y2/Y3) M1158 X6 D1353 D1349 D1352 D1234/D12 35 D1135 D1136 D1102 D1103