3. Instruction Set performed before 50,000 pulses are achieved. Points to note: When Mark function is executed with Mask function, PLC will check the validity of Mask range first, then ramp-down stop pulses of Mark function. If the above set values exceed the proper range, PLC will automatically modify the set values after the instruction is executed. When PLSR or positioning instructions with ramp-up/down section are enabled, the user can check the pulses of ramp-up section in DD1127 and pulses of ramp-down section in DD1133. Users can perform single speed positioning when ramp-up/down time setting is not specified. 5.
Adding mask and alignment mark function for CH0 and CH1 Available for the followings CH0 and CH1 relative parameters for Mask and Alignment Mark function: 3-153 ES2/ 12SA2/ Series ES2-C ES2-E SS2 12SE 26SE 28SA2 EX2 SX2 Firmware V3.28 V3.28 V1.00 V2.82 V3.28 -- V2.0 V3.0 version Output number Marking deceleration flag External input point Ramp-up time Ramp-down time Starting/ Stopping frequency Number of Front masking Back masking ramp-down pulses after marking CH0 (Y0/Y1) M1156 X4 D1343 D1348 D1340 D1232/D12 33 D1026 D1027 D1100 D1101 CH1 (Y2/Y3) M1158 X6 D1353 D1349 D1352 D1234/D12 35 D1135 D1136 D1102 D1103