3. Instruction Set The frequency for the fixed slope is defined by the frequencies of starting, ending and the maximum as well as the time of ramp-up and down. See the red line for reference. 7. Add new functions such as adding alignment marks to the ramping down, the frequency of the fixed slope and selected masking for the output points Y1 and Y3. The actions are the same as aforementioned 5 and 6. And the relative parameters are listed below. Available for the followings Special D/M Devices Corresponding to the Marking and Masking Function It does not support separating the ramp up and ramp down nor does it support setting up the start/stop frequency.
3-155 ES2/ 12SA2/ Series ES2-C ES2-E SS2 12SE 26SE 28SA2 EX2 SX2 Firmware V3.42 V3.48 V1.00 V2.86 -- -- -- V3.0 version Output number Marking deceleration flag External input point Ramp-up time Ramp-down time Starting/ Stopping frequency Number of Front masking Back masking ramp-down pulses after marking Y0 M1156 X4 D1343 D1348 D1340 D1232/D1233 D1026/ D1027 D1100/ D1101 Y1 M1157 X5 NA NA NA D1236/D1237 D1154/ D1155 D1156/ D1157 Y2 M1158 X6 D1353 D1349 D1352 D1234/D1235 D1135/ D1136 D1102/ D1103 Y3 M1159 X7 NA NA NA D1238/D1239 D1158/ D1159 D1160/ D1161