Delta DVP-ES2 — 3.8 Detailed Instruction Explanation

DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming  Y1 and Y3 relative parameters for fixed slope function: Note: If the values in the device where stores pulse number for masking in the front for Y0-Y3 is zero or less than -4 or equals to -4, it indicates the marking and masking functions in the front are disabled. On the other hand, if the values is greater than 0 or between -1 to -3, it indicates the marking and masking functions in the front are enabled. If the values in the device where stores pulse number for masking in the back for Y0-Y3 is less than 0 or equals to 0, it indicates the marking and masking functions in the back are disabled.

On the other hand, if the values is greater than 0 or if the values in the device where stores pulse number for masking in the front is less than -3, it indicates the marking and masking functions in the back are enabled. 8. PLSR/DPLSR Instructions  Added new marking behaviors A-C for PLSR/DPLSR instructions and behavior B (-3) for DCLLM instruction. Applicable Models and Starting Versions Descriptions of behaviors A-C A. When the number of pulses is not sufficient to complete acceleration/deceleration, marking and masking are added in the area. See the Y0 example below. The masking in D1026/1027 of the front masking area and D1100/1101 of the back masking area are effective. B.

When the masking number is -1 in the front masking area, it indicates masking occurs in the acceleration area; -2 in the front masking area means masking occurs in the areas of acceleration and full-speed; -3 (only available for DCLLM instruction) in the front masking area means masking occurs in the areas of acceleration, full-speed and deceleration. 3-156 Output Flag for fixed slope Special device for the maximum frequency Y1 M1606 D1988,D1989 Y3 M1607 D1990,D1991 Series ES2/EX2/ES2-C ES2-E 12SA2/SX2 SS2 12SE 26SE 28SA2 Firmware V3.60 V1.20 V3.00 -- V2.02 V2.02 V3.0