DVP-ES2/EX2/SS2/SA2/SX2/SE&TP Operation Manual - Programming 10. When M1 changes from OFF to ON, the setting for servo is as below. 11. Any error occurs during operation, M1616 will be set to ON and the servo drive number that shows error will be stored in D6000, error codes in D6001 and STEP that when error occurs in D6002. 12. For corresponding SM and SR of the axes, refer to the DRVIC instruction (API331). Example 1 1. When M0 changes from OFF to ON, the INITC instruction starts to initialize the servos at station addresses 1–3 (should be in a consecutive order) The station address must start at 1 and the following addresses cannot be skipped or reserved.

Set the acceleration time of servo 1 to 3000 ms and the deceleration time to 9000 ms, until M1615 is ON. 2. When M1615 is ON, the instruction starts enable the servo at station 1 and SM1640 is ON, indicating Servo-ON. 3. When M1 changes from OFF to ON, the setting for servo is as below. 4. When M6 changes from OFF to ON, the homing function is enabled for servo 1. After homing is complete, M1624 is ON.

3-558 Parameters Description CANopen address P5-04 (16bit) Homing mode H2504 P6-00 (32bit) Homing setting H2600 P6-01 (32bit) Origin definition H2601 CANopen Setting Completion Parameters Description address value flag P5-04 (16bit) Homing mode H2504 D110=K3 M105 P6-00 (32bit) Homing setting H2600 D112=K0 M106 P6-01 (32bit) Origin definition H2601 D114=K0 M107