Chapter 6 Applied Instructions Additional remarks 1. The following graph explains the relative positioning by specifying the travel distance from the current position with the +/- signs. Frequency + , 3 000 pulse Target frequency Start/end frequency Current position - 3 000 pulse , 2. Setting the ramp up/down and the items for relative positioning a) Y0 output curve diagram Frequency Slope ramp-up 6_ Start/end frequency SR463 Time SR465 Ramp-up time Ramp-down time b) You can create several DRVI instructions using the same output point in the program. The PLC can start SR464 only one DRVI instruction when executing the program.
For example, when one instruction starts Y0 for output, then other instructions that also use Y0 for output are not executed. The instruction that starts the output point first uses the point first. c) After the instruction is executed, any modification of the parameters is not accepted until the instruction is disabled. 6-795 Number of S1: output pulses S2