Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

DVP-ES3 Series Programming Manual c) Operation of the negative limit  Negative software limit position is set in HWCONFIG (by setting SR582 = –11,000 for example). After downloading the setting to the PLC, the negative limit function starts.  DDRVI starts to output 20,000 pulses in the negative direction. Note: the instruction does not output in the negative direction if the negative limit is exceeded when the function starts.  When the current position SR460 function is met.  DDRVI instruction stops the output immediately and the negative limit alarm SM467 is ON.  If the condition for the software limit function is not met, Y0 stops the output after -20,000 pulses.

d) Rising-edge trigger e) SR related to the limit function _6 Positive output limit: the output stops immediately if the current position is greater than the positive limit position. Negative output limit: the output stops immediately if the current position is less than the negative limit position. When the positive and negative limits are both 0, the software limit function cannot start. Since the software limit function checks the output position when the output instruction is scanned, stopping the output is affected by the PLC scan. To quickly stop the output in real time, use the external input point as the limit point.

6-800 Limit function Contact A Contact B Types Rising-edge trigger Falling-edgetrigger Descriptions When started: from low to high and maintains at high When started: from high to low and maintains at low Axis number Axis 1 Axis 2 Axis 3 Axis 4 Positive software limit position SR580 SR581 SR584 SR585 SR588 SR589 SR592 SR593 Negative software limit position SR582 SR583 SR586 SR587 SR590 SR591 SR594 SR595