Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

Chapter 6 Applied Instructions 10. If the output has entered the ramp-down process when the external input interrupt trigger occurs, the instruction completes the output of the number of pulses specified by S 6. 11. See the following timing diagram about the output, interrupt trigger, mask and relevant flags. For the completion flag, refer to the Completion flag SM for the axes in DDRVI instruction (API 2706). EN S 4 S 5 S 3 finish flag S 2 D 1 Time Pulse No. S 6 0 S 1 12. The target frequency S 2 of the instruction can be modified in the process of the pulse output.

Since the number of output pulses in the ramp-down section has been set when the instruction is executed, the timing diagram for changing the frequency is shown as the following dashed line. 6_ S 3 Change S 2 D 1 S 2 Time Pulse No. 13. Refer to the DDRVI instruction (API 2706) for the selection of pulse output devices for D 1 and D 2. The output points S 6 for D 1 can only be even-numberd such as Y0, Y2 or Y6. If the output points are not the recommended ones, the direction output D 2 is affected by the scan cycle. 14. The instruction cannot be used in the ST programming language, interrupt tasks or function block which is called only once. 6-813