Chapter 6 Applied Instructions Additional remarks 1. The alignment mark function and mask function: When DDRVM is executed, the pulse output starts. When the interrupt occurs for the mark alignment, the ramp-down process starts and the output stops after the number of the pulses specified by S 6 . When the interrupt for the mark alignment does not occur or has no effect, DDRVM stops outputting the pulses after the target number of pulses specified by S 1 . S 4 : The number of output pulses in the fore mask section. If the interrupt occurs in this section, the interrupt is ineffective for the mark alignment. S 5 : The number of output pulses in the rear mask section.
If the interrupt occurs in this section, the interrupt is ineffective for the mark alignment. S 2 : The target output frequency 6_ 6-815