Delta DVP-ES3 — 6.26.2 Explanation of High-speed Output Instructions

DVP-ES3 Series Programming Manual 5. Select the zero return mode. The function code is set by the two high and low16-bit parameters. See the following table for details. 6. The function code is set by the two high and low 16-bit parameters. See the following table for details. _6 6-868 Select the zero return mode High 16-bit Low 16-bit b31~b16 b15~b6 b5 b4 b3~b0 Number of pulses for motion reserved Setting NL signal 0: contact A 1: contact B Setting DOG signal 0: contact A 1:

contact B Mode settig 0~2; 8~10 Functions Code Description High Low 16-bit 16-bit Leaves the zero point in the negative direction and then stops (Mode 0) 0 0 When the instruction is executed, the search for the zero point is in the negative direction with the target frequency. When the zero point is ON (the zero point signal changes from OFF to ON), the frequency is decreased to the JOG speed and the motion in the negative direction continues, and does not stop until the zero point signal changes from ON to OFF.

Leaves the zero point in the positive direction and then stops (Mode 1) 0 1 When the instruction is executed, the search for the zero point is in the negative direction with the target frequency. When the zero point is ON (the zero point signal changes from OFF to ON), the frequency decreases to 0 immediately, and then the motion is in the positive direction at the JOG speed, and does not stop until the zero point signal changes from ON to OFF. Mode 0 Moves again after returning to the zero point Number of pulses for motion 2 Returning to the zero point is the same as that for the low 16-bit code. After the zero point is ON, the motion continues according to the number of specified pulses.

When the high 16-bit code is a positive number, the search is in the positive direction. A negative value means that the search is in the negative direction. Leaves the zero point in the positive direction and then stops (Mode 1) 0 8+0=8 8+1=9 (bit3=ON) Refer to mode 1. The operation for zero point return is the same as that for code 1 (mode 1). Mode 1 outputs the number of pulses after returning to the zero point Number of pulses for motion 8+2=10 (bit3=ON) The operation for zero point return is the same as that for low 16-bit code 1. After returning to the zero point, the motion continues in accordance with the number of specified pulses.

When the value of the high 16-bit code is a positive number, the motion is in the positive direction. A negative number indicates