Delta DVP-ES3 — 6.27.2 Explanation of CANopen Communication Instructions

DVP-ES3 Series Programming Manual 6.27.2 Explanation of CANopen Communication Instructions Symbol S : Number of station to be initialized Explanation _6 1. Before executing the instruction, be sure to set up CANopen Communication settings, including work mode: Delta Special Driver or Delta Special Driver & CANopen DS 301 and bit rate.  Work Mode: Go to HWCONFIG -> Settings -> Options -> Built-in CAN Communication -> CAN port work mode : Delta Special Driver / Delta Special Driver & CANopen DS 301.  Bit rate: Go to HWCONFIG -> Settings -> Options -> Built-in CAN Communication -> CAN bit rate -> 10K~1000K. 2. The servo range of S is 1–8.

When the input value is greater than 8, PLC automatically processes 8 as value of S for the initialization. The station address must start at 1 and the following addresses cannot be skipped or reserved. 3. S ranging from 21 to 28 is added for inverters. For the input value that is not in the range of 21 to 28, this instruction will not be executed. Same rule applies to the servo; the station address must start at 21 and the following address should be in consecutive order. 4. When setting the number of station to be initialized to 5, this instruction initializes station address from 1 to 5.

And when setting the number of station to be initialized to 23, this instruction initializes station address from 21 to 23. When there are 5 servo systems and 3 inverters that need to be initialized, you need to execute this instruction twice. One is INITC 5 for 5 servo systems and the other is INITC 23 for 3 inverters. 6-874 API Instruction Operand Description 2800 INITC S Initializing the servo for CANopen communication Device X Y M S T C HC D FR SM SR E K 16# “$” F S   BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S  Pulse Instruction 16-bit instruction 32-bit instruction - ES3 -