EA180 Series Servo Drive Users Manual 4.10 Auxiliary function operation * This parameter will be stored and the drive will be enabled ON immediately upon the next power-on. If this is not desired, please modify this parameter value to 0 before power-off. 50 Data size 16bit Commu. addr. 3F00H Software reset Register value storage Auto reset upon completion Register Display Operation value AF-00 0 0 -End- S Press , it displays , no operation 1 rEs Et S Press to reset software (equivalent to power-on again of control power supply) Data size 16bit Commu. addr.
3F01H Alarm reset Register value storage Auto reset upon completion Register Display Operation value AF-01 0 0 Press S , it displays -End- , no operation AlClr Press S to perform the alarm reset operation 1 * It must be a resettable alarm and the cause of current alert has been eliminated. Data size 16bit Commu. addr. 3F02H JOG Register value storage - Register Display Operation value snur rotom eht , ˅ sserP . gojs syalpsid ti dna drawrof setator rotom eht , ˄ sserP _ AF-02 reversely and it displays _sjog . Do not press the key, motor is static, display -sjog - -sjog * The speed of jog operation is determined by P8-00, and the acc/dec time is determined by P8-01.
lliw ssecorp goj eht dna ,etats )ydaer dna ,delbane ton( ydrp . eht ni etarepo esaelP * _ automatically exit if a warning occurs. Data size 16bit Commu. addr. 3F03H Internal S ON command Register value storage Stored _ Register Display Operation value AF-03 0 -End- Press S to display . If there is no other enable input, the drive will enter the 0 enable OFF state. s-on s-on If the enable condition is met, press S to display , and the drive will enter the 1 enable-ON state. Data size 16bit Commu. addr.
3F04H FFT test Register value storage Auto reset upon completion Register Display Operation value 0 0 -End- Press S , it displays , no operation AF-04 Eydft Press S , and it displays and carries out speed bandwidth test with the upper Eyd ft 1 ft device software identification system; after the test, automatically exit and upload the data to the upper device for analysis and display. * The motor has slight vibration and sound. Data size 16bit Commu. addr.
3F05H Offline inertia identification Register value storage Auto reset upon completion Register Display Operation value AF-05 0 0 Press S , it displays -End- , no operation Press S , it displays jIdt and starts to identify the current system inertia. After jI dt 1 dt successful identification, the inertia (multiple of the motor inertia) is automatically stored in P4-10. * Refer to Section 6.6 for detailed description of inertia identification.