User Manual EM303B General Purpose Inverter Because F0-00is read only, inverter responds error message. Inverter responds data frame in hexadecimal format Command code is 86H in error message, the highest bit 1 of 06H. If error code detail is 11H, it means the parameter is read only. After responding to the error data receipt, master can revise the responding program via resending data frame or based on the error message responded by the inverter. 12.5.6 Details of 0x08 Circuit Diagnoses and Setting 13.6 Description of Control Command Control Command 1(Register Address: 4000H or 7000H) Control Command 2(Register Address: 4000H) Virtual Terminals from LSB to MSB are:
X1, X2, X3, X4, X5, X6, X7, VS, VF, IS, IF, Y1, Y2, R1. Inverter Status 1(Register Address:
4100H) 182 01H 86H 11H 82H 6CH Sub-function Code Indication of Data Requested Response Data Sub-function 0000H #data16 The same as the data requested Circuit Diagnosis Data Meaning Data Meaning 0000H Disabled Command 0006H Ramp to Stop 0001H Forward Running 0007H Coast to Stop 0002H Reverse Running 0008H Fault Reset 0003H JOG Forward 0009H +/- Input Switch 0004H JOG Reverse 000AH Not Used 0005H Slave-inverter Stops 000BH Not Used Virtual Terminals R1 Y2 Y1 IF IS VF VS X7 X6 X5 X4 X3 X2 X1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Data Meaning Data Meaning 0000H Parameter Setting 0004H Slave-inverter Stops 0001H Slave-inverter Runs 0005H JOG Stop 0002H JOG Running 0006H Fault Status 0003H Running in Autotuning 0007H Factory Check