EM500 Open-Loop Vector Control Inverter User Manual 181 Speed Control and Torque Control and F13.00: if no.28 terminal is enabled, the control mode of inverter will switch between speed control and torque control; if no.29 terminal is enabled, only the speed control works. See F13.00 for details. 29 Torque Control Disabled 30 Switch between Motor 1 and Motor 2 This terminal and F00.28 are used together to determine present set motor: if no.30 terminal is enabled, the switch can be completed based upon F00.28. See F00.28 for details.
31 Simple PLC Status Reset (Start to Run with Preset Speed 1, Clear Running time) When this terminal is enabled, simple PLC module will start to run again from the first preset speed. To further understand this function, user may view the simple PLC description of F08. 32 Simple PLC Time Pause (Keep Running at Preset Speed) When this terminal is enabled, the simple PLC module will keep running at present speed; after it is disabled, the simple PLC module will continue running after present speed stage is completed. 33 Not used 34 Count Input (≤250Hz) The pulse input terminal with the count function limits the input pulse frequency to ≤250Hz. Only one terminal can be set with this function.
See F16.03 - F16.04 for details 35 High-Speed Count Input (≤100kHz, Only Enabled for X7) The pulse input terminal with the count function limits the input pulse frequency to ≤100kHz. Only one terminal can be set with this function. See F16.03 - F16.04 for details. 36 Counter Clear Clear the counter that has the counter function 37 Length Count Input (≤250Hz) The pulse input terminal with the length count function limits the input pulse frequency to ≤250 Hz. Only one terminal can be set with this function. See F16.01 - F16.02 for details.
38 High-Speed Length Count Input (≤100kHz, Only Enabled for X7) The pulse input terminal with the count function limits the input pulse frequency to ≤100kHz. This terminal is only enabled for X7 (i.e., F02.06=38). See F16.01 - F16.02 for details 39 Length Clear A length clear terminal with the length count function 40 Pulse Input (≤100kHz, Only Enabled for X7) This is a pulse signal input terminal with the input pulse frequency ≤100kHz. It is only enabled for X7. ★ This function can not be used for special functions (for example, count). This terminal is only used as the setting equivalent to AI percentage. If F00.04=5, then set F02.06=40 and set the frequency pulse through the terminal X7.
41 Process PIC Pause When this terminal is enabled, then PID stops the adjustment. At this time, the process maintains the output. For more