EM500 Open-Loop Vector Control Inverter User Manual EM500 inverter supports the high-speed pulse output (HDO) function, which is similar to the analog output function. The output of inverter is in pulse of different frequency sizes other than voltage values. When inverter is in jog running, user does not need DO to output some status, so setting this function code as 1 to shield corresponding output. If F03.08=xxx1x when FAR is in active output status, then the actually selected output terminal does not output the active level. This function code is of bit operation type. For specific settings, please refer to table 7-5 of F02.15.
Function i Output Active Inactive TTiTT TT TT Level Output Active Inactive TTTT TT TT Ineffective Delay Time TTTT Monopulse Output Active Inactive TTTTT TT TT Pulse Output Width TTTTTT Figure 7-16 Numeric Output Terminal Level and Monopulse Output 200 No. Function Range Unit Default Type F03.08 Output Status Control at JOG D7 D6 D5 D4 D3 D2 D1 D0 00000 〇 * * * REV FDT2 FDT1 FAR RUN 0: Enabled at JOG 1: Disabled at JOG No.
Function Range Unit Default Type F03.09 Y1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.10 Y1 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F03.11 Y2 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.12 Y2 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F03.13 R1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.14 R1 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F03.15 R2 Effective Delay Time 0.000 - 30.000 s 0.000 ● F03.16 R2 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● EffecTtivTe T T Time Delay