EM500 Open-Loop Vector Control Inverter User Manual 1. In order to meet the requirements of various instruments or peripherals, the full-scale voltage of M1 and M2 is 10.9V actually and the full-scale current is 22mA actually. 2. The default settings of M1 and M2 are 0.00 - 10.00 V. 3. Please use a multimeter to test the idling output of terminals M1 and M2, if there is h requirement on the accuracy of the analog output. 7.5 F04 Group: Start/Stop Control Parameter F04.00=0:
Start Directly Inverter starts with DC brake (not available if F04.04=0), conducts the pre-excitation (not available if F04.07=0), starts at the start frequency, and enters the set frequency running after the retention time of the start frequency. F04.00=1: Rotation Speed Tracking Start Inverter will first perform the rotation speed tracking (size and direction) at startup, and start up smoothly from the actual rotation frequency of present motor Set an appropriate start frequency, in order to guarantee motor torque at start. In order to enable motor to make magnetic flux fully, it’s required to maintain motor’s start frequency for certain time.
The start frequency F04.01 is not limited by the lower limit frequency. Before inverter starts, motor may run at low speed or reverse. Starting inverter at 204 No. Function Range Unit Default Type F04.00 Start Mode 0: Start Directly 1: Rotation Speed Tracking Start 0 〇 No. Function Range Unit Default Type F04.01 Start Frequency 0.00 - 10.00 Hz 0.00 〇 F04.02 Start Frequency Retention Time 0.00 - 60.00, Disabled at 0.00 s 0.00 〇 No. Function Range Unit Default Type F04.03 DC Brake Current at Start 0.0 - 100.0 (100.0= Motor Rated Current) % 100.0 〇 F04.04 DC Brake Time at Start 0.00 - 30.00 s 0.00 〇