sinee — 7.5 F04 Group: Start/Stop Control Parameter

EM500 Open-Loop Vector Control Inverter User Manual F04.14=0: Linear Acceleration/Deceleration Output frequency increases or decreases in a straight line progressively and the default acceleration/deceleration time is set through the function codes F00.14 and F00.15. F04.14=1: S curve acceleration/deceleration During the acceleration in Figure 7–15: t1 is the value set through F04.15 and t2 is the value set through F04.16; during the deceleration: t3 is the value set through F04.17 and t4 is the value set through F04.18.During the time period of t1 and t2, and t3 and t4, the gradient for output frequency changes is fixed.

207 Section Time at Acceleration (F15.13=0) 0.0 - System acceleration time/2 (F15.13=1) 0 - System acceleration time/2 (F15.13=2) F04.16 S Curve End Section Time at Acceleration 0.00 - System acceleration time/2 (F15.13=0) 0.0 - System acceleration time/2 (F15.13=1) 0 - System acceleration time/2 (F15.13=2) s 1.00 ● F04.17 S Curve Start Section Time at Deceleration 0.00 - System deceleration time/2 (F15.13=0) 0.0 - System deceleration time/2 (F15.13=1) 0 - System deceleration time/2 (F15.13=2) s 1.00 ● F04.18 S Curve End Section Time at Deceleration 0.00 - System deceleration time/2 (F15.13=0) 0.0 - System deceleration time/2 (F15.13=1) 0 - System deceleration time/2 (F15.13=2) s 1.00 ●