EM500 Open-Loop Vector Control Inverter User Manual In VVF, adjusting this parameter can suppress motor oscillation. However, do not adjust it or adjust this parameter to a smaller value properly if there is no motor oscillation; in case of apparent oscillation, adjust this parameter to a bigger parameter properly. This function is usually applied to the load distribution when multiple motors bear one load. Inverter output frequency goes down as the load increases; when multiple motors bear the same one load, motor output frequency for the load will decrease more, thus reducing the load of motor and realizing the even load of multiple motors.
This parameter refers to the decline of output frequency when inverter is in rated load output. The energy saving rate (F05.16) indicates the energy saving capacity. The higher the set value is, the better the energy saving effect will be. If it is set as 0.00, the energy saving is disabled. When the energy saving running is enabled, the energy saving conditions are reached and the energy saving actuation time (F05.17) is maintained, then the energy saving control will start. 216 No. Function Range Unit Default Type F05.13 Oscillation Suppression Gain 0 - 20000 100 ● F05.14 Oscillation Suppression End Frequency 0.00 - 600.00 Hz 55.00 ● No.
Function Range Unit Default Type F05.15 Sagging Control Frequency 0.00 - 10.00 Hz 0.00 ● No. Function Range Unit Default Type F05.16 Energy Saving Rate 0.00 - 50.00 % 0.00 ● F05.17 Energy Saving Actuation Time 1.00 - 60.00 s 5.00 ● No. Function Range Unit Default Type F05.18 Compensation Gain of Magnetic Flux of Synchronous Motor 0.00 - 500.00 % 100.00 ● F05.19 Filter Time Constant of 0.00 - 10.00 s 0.50 ●