EM500 Open-Loop Vector Control Inverter User Manual The high frequency current injection method realizes the detection of the initial position of the rotor. When inverter is in stationary status, inject the high frequency current to motor stator winding so as to estimate motor rotor position accurately by taking advantage of saliency effect and magnetic flux saturation characteristics and detecting the time of the high frequency current peak. According to the experimental result, this method does not have a high accuracy or depend upon any motor parameter.
223 at Low Frequency Range F06.29 Injection Current at Low Frequency Range 0.0 - 60.0 (100.0= Motor Rated Current) % 20.0 ● F06.30 Low Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F06.31 Integral Time of Low Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ● F06.32 Frequency of Injection Current at High Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 20.00 ● F06.33 Injection Current at High Frequency Range 0.0 - 30.0 (100.0= Motor Rated Current) % 8.0 ● F06.34 High Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F06.35 Integral Time of High Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ●