EM500 Open-Loop Vector Control Inverter User Manual The feedback voltage upper and lower limits can be used for automatic Material supply disruptions detection of the winding application, which represent the upper and lower bounds of the Material supply disruptions, respectively. Due to the particularity of the winding application, F09.35 and F09.36 can be Used to reflect the real sensor boundaries, which is more conducive to system stability. F09.37=0:
Always calculated integral item This function code does not affect the integral effect F09.37=1 F09.21 began calculating integral item When set time has arrived The first F09.21 changes within the time set after starting does not work F09.37=2 when the error is less than F09.38 Start calculating integral item The first F09.21 changes within the time set after starting does not work, however, if the error is less than F09.38 in this time, the Integral re-effect7.11 F10 Group: Communication Function Parameter EM500 inverter supports Modbus protocol of RTU format, and the with single-master and multi-slave communication network with RS485 bus (see Chapter 12). 251 No.
Function Range Unit Default Type The Feedback Voltage The feedback voltage lower F09.35 V 10.00 ● Upper Limit limit~10.00 The Feedback Voltage 0.00~ The Feedback Voltage F09.36 V 0.00 ● Lower Limit Upper Limit No. Function Range Unit Default Type 0: Always calculated integral item 1: F09.21 began calculating PID Integral Action ● integral item When set time F09.37 Choice Given Change 0 has arrived Time 2: when the error is less than F09.38 Start calculating integral item PID Integral Action F09.38 Given Change Ttime 0.00-100.00 % 30.00 ● Input Deviation