sinee — 7.14 F13 Group: Torque Control Parameter

EM500 Open-Loop Vector Control Inverter User Manual F13.01=8: Digital Potentiometer Setting Torque mode, the torque given directly by the digital potentiometer, the specific value can see F12.43 To realize the diversification of the torque application, EM500 inverter supports the preset torque function. Set the input terminal “17: Preset Torque Terminal 1” and “18: Preset Torque Terminal 2”. See Table 7-19 for details Table 7-19 Preset Torque Commands and Preset Torque Terminals Setting F13.06 can make the motor speed change smoothly The value set by F13.06 refers to the time that the torque current increases from 0 to the rated torque current or decreases from the rated current to 0.

275 No. Function Range Unit Default Type F13.03 Preset Torque 1 -200.0 - 200.0 % 0 .0 ● F13.04 Preset Torque 12 -200.0 - 200.0 % 0 .0 ● F13.05 Preset Torque 13 -200.0 - 200.0 % 0 .0 ● 18: Preset Torque Terminal 2 17: Preset Torque Torque Torque Terminal 1 Disabled Disabled Preset Torque 1 Set through F13.01 Disabled Enabled Preset Torque 1 F13.03 Enabled Disabled Preset Torque 1 F13.04 Enabled Enabled Preset Torque 1 F13.05 No. Function Range Unit Default Type F13.06 Torque Control Acceleration/Decelerat ion Time 0.00 - 120.00 s 0.05 ● No. Function Range Unit Default Type F13.08 Upper Limit Frequency of Torque Control 0: Set through F13.09 1: AI1 2: AI2 3: AI3 4: AI4 (Expansion Card) 0 〇