sinee — 7.16 F15 Group: Auxiliary Function

EM500 Open-Loop Vector Control Inverter User Manual For PWM modulation method, if F15.36=0, the 7 preset PWM modulation always applies; if F15.36=1, the 7 preset PWM modulation applies when output frequency is lower than the switching frequency (F15.37), or the 5 present PWM modulation applies when output frequency is greater than the switching frequency,.In comparison with the 5 preset PWM modulation mode, the current ripple wave for the 7 preset PWM modulation mode is smaller, but the switching loss is higher, and inverter would have a higher heating level and a higher temperature rise. User does not need to change the option of this function code.

Only when there are special requirements on output voltage waveform quality or motor is in an abnormal status (for example oscillation) would user try to select a different compensation mode. Generally, the compensation mode 1 is selected, but user may select the compensation mode 2 in case of high power and VF control, which may easily cause motor oscillation. Under terminal control mode (F00.02=1), this function code is used to select whether there is jog priority.

For the terminal jog priority (F15.39=1), inverter changes to the jog running status if the jog terminal is enabled, even if inverter is running; if F15.39=0, inverter cannot change to the jog running status from the running status directly. 290 No. Function Range Unit Default Type F15.36 PWM Modulation Method Switching Options 0: Disabled (7 preset PWM modulation) 1: Enabled (5 preset PWM modulation) 0 〇 F15.37 PWM Modulation Method Switching Frequency 0.00 - Maximum Frequency F00.16 Hz 15.00 ● No. Function Range Unit Default Type F15.38 Deadband Compensation Mode 0: Disabled 1: Compensation Mode 1 2: Compensation Mode 2 1 〇 No.

Function Range Unit Default Type F15.39 Terminal Jog Priority 0: Disabled 1: Enabled 0 〇 No. Function Range Unit Default Type F15.40 Deceleration Time at Rapid Stop 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 1.00 ●