EM500 Open-Loop Vector Control Inverter User Manual F16.00=0: General models As a General models inverter, the application-related functions are not enabled F16.00=1: Application of Water supply Using PID adjustment of constant pressure water supply control, and optional clock card, it can provide clock pressure setting function. F16.00=2: Application of Air compressor Using PID adjustment of air compressor control, and optional air compressor interface card, PT100 temperature can be calculated automatically. F16.00=3: Application of Winding PID control with dancer feedback.
Changing this function code activates the corresponding functions only, please manually restore the factory settings through F12.14 to obtain special parameters. EM500 inverter has the fixed length count function (refer to Figure 7-40). Inverter 293 No. Function Range Unit Default Type F16.01 Set up length 1~65535(F16.13=0 ) 0.1~6553.5(F16.13 =1) 0.01~655.35(F16.1 3=2) 0.001~65.535(F16. 13=3) m 1000 ● F16.02 Pulse Count Per Meter 0.1 - 6553.5 100.0 ● F16.13 Set Resolution Of The Length 0: 1m 1: 0.1m 2: 0.01m 3: 0.001m 0 〇