EM500 Open-Loop Vector Control Inverter User Manual must input the length information via the numeric input terminal in the form of pulse before setting relevant function codes to complete the length count function. The completion information of the final length count can be outputted via the numeric output terminal and other methods for other purposes (for example, input it via DI/VX to be used as a stop command). User may also view present length count value through F18.34.
DI “Length Count” Input meter a (0.1 - 6553.5) p/m Pulse count per F18.3 4 Length Senso r Divider Comparer Length Pulse HDI “Rapid Length Count” Input (Function of No.37) (Function of No.38) Pulse count CntIn Clear Length 11 Lgth ≥ Reset Set Length 1 (1- 65535) m Length Clear Signal DI “Length Clear” Input (Function of No.38) Figure 7-40 Block Diagram of Fix Length Count Function into the pulse information; DI terminal collects the input pulse number N; according to Operation principle:
The length detection sensor transforms the length information the setting of “Pulse Count per Meter” as , we can know that the length is N l 1 , and then compare it with the “Set Length l ”.If 1 l l , it means that the length has not reached the set value; otherwise, this function is completed.““39: Length Clear” is used to clear the count and reset the output signal. If the pulse frequency is greater than 250 Hz (=1/(2(default filter times)*2*1ms -1 )), please complete the input via X7 and set F02.06 as “38: High-Speed Length Count Input”. 250 Hz is just a theoretical value. The actual value will apply. To avoid any mistake, please use the high speed pulse input terminal.
2 1 3 4 5 6 7 8 9 10 11 Pulse Count Value 2 1 3 4 5 6 7 8 9 9 0 0 Input Disabled Enabled Clear Length Reach Disabled Enabled Disabled Figure 7-41 Fixed Length Count (Example) 294 DO “Length Reach” Output (Function of No.16) Length Reach Signal