sinee — 7.17 F16 Group: User Defined Function Parameter

EM500 Open-Loop Vector Control Inverter User Manual to the remaining time.hat is to say, a timed run procedure starts from inverter running. After inverter stops, the accumulated time is cleared. Agent Password ★ By setting this password, inverter may not be used normally. Please pay enough attention. These codes are used to set the accumulated power-on reach time. When the accumulated power-on time (F12.15/16) ≥ the accumulated power-on reach time (F16.07), inverter can not be used. ★ By setting this parameter, inverter may not be used normally. Please pay enough attention This function is used to set accumulated running arrival time.

When accumulated running time, if (F12.17/18) ≥ the set accumulated running arrival time (F16.08), inverter can not be used. ★ By setting this parameter, inverter may not be used normally. Please pay enough attention Factory Password ★ By setting this password, inverter may not be used normally. Please pay enough attention 297 No. Function Range Unit Default Type F16.06 Agent Password 0 - 65535 0 〇 No. Function Range Unit Default Type F16.07 Set Accumulated Power-On Time Reach 0 - 65535, 0: Power-on Reach Time Protection Disabled h 0 〇 No. Function Range Unit Default Type F16.08 Set Accumulated Running arrival time 0 - 65535, 0: Running time Reach Protection Disabled h 0 〇 No.

Function Range Unit Default Type F16.09 Factory Password 0 - 65535 XXXXX ● No. Function Range Unit Default Type