sinee — 7.18 F17 Group: Virtual I/O Function Parameter

EM500 Open-Loop Vector Control Inverter User Manual physical terminal, but they all have the positive/negative logic function. VX1 - VX4 have In terms of functions, VX1 - VX8 are basically the same; they do not have an actual the delay function, with the same terminal status confirmation method; they can be set respectively. An example is given to VX1 in the following part.  If F17.09=xxxxxxx0, VX1 status and VY1 output status are the same. 300 Function F17.08 Positive/Negative Logic of Virtual Input D7 D6 D5 D4 D3 D2 D1 D0 000 00000 〇 VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 0: Positive Logic, Enabled at On/Disabled at Off 1:

Negative Logic, Disabled at On/Enabled at Off F17.11 VX1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.12 VX1 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F17.13 VX2 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.14 VX2 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F17.15 VX3 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.16 VX3 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F17.17 VX4 Effective Delay Time 0.000 - 30.000 s 0.000 ● F17.18 VX4 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● No. Function Range Unit Default Type F17.09 VX1 - VX8 Status Setting D7 D6 D5 D4 D3 D2 D1 D0 000 00000 〇 VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 0: VXn Is Same as VYn Output 1:

Status to be Set by F17.10 F17.10 VX1 - VX8 Status Setting D7 D6 D5 D4 D3 D2 D1 D0 000 00000 ● vx8 vx7 vx6 vx5 vx4 vx3 vx2 vx1 0: Disabled 1: Enabled