sinee — 7.18 F17 Group: Virtual I/O Function Parameter

EM500 Open-Loop Vector Control Inverter User Manual As mentioned above, the virtual input terminal has the same status as the virtual output terminal. At this time, it needs to be used together with the virtual output terminal. If F17.19=16 and F17.28=0bxxxx xxx1 (VY1 output status is determined by the output function status) under default conditions, then when “16: Length Reach” is enabled, VY1 is enabled and VX1 is enabled as well; at this time, setting this function as per VX1 (assuming 39: Length Clear) to complete corresponding operations (clear the length count and reset VY1). Now, the fixed length count function can start again to realize the repeated processing requirements.

If time interval is needed for repeated processing times, we can realize this function by VX1 delay. function code F17.10 If F17.09=xxxxxxx1, the status of VX1 is determined by the bit0 of the The status of the virtual input terminals can be set by the function codes. This method is mainly used for the remote control of host controller. The remote control terminal may use the function code 0x41 to change the status setting of F17.10 EM500 inverter has 8 multi-function virtual output terminals (VY1 - VY8). Their (enabled or disabled) via communication. functions and use methods are basically the same as actual output terminals. In the following, only the difference will be described.

For the same functions and use methods as that of actual input terminals, please refer to the descriptions of F03 Output Terminal Function Parameter. 301 Uni Defau No. Function Range Type t lt F17.19 VY1 Virtual Output Function Same as the options of F03 group numeric output terminals, please refer to Table 7-6 Numeric Multi-Function Output Terminals 0 〇 F17.20 VY2Virtual Output Function 0 〇 F17.21 VY3 Virtual Output Function 0 〇 F17.22 VY4 Virtual Output 0 〇