EM500 Open-Loop Vector Control Inverter User Manual If F17.28=xxxxxxx0, VY1 status and X1 input status are the same. The status of VY1 is synchronized with actual input status X1. This application can be used for status confirmation and one switch motion can be used for realizing the programming of multiple functions, etc If F17.28=xxxxxxx1, the status of VY1 is determined by F17.19. The status of the virtual output terminal is determined by the set status. Such output is mainly used for soft programming. For example, we can output the signal of “19:
PID Feedback Upper Limit Reach” via VY1 (F17.19=19), and collect the signal via VX1 (F17.00=41), in order to control PID via the function code “PID Feedback Upper Limit Reach”. These function codes are used to display present virtual terminal status in real time. 7.19 F18 Group: Monitoring Parameter This group of parameters can be used for viewing present status of inverter, but cannot be used to operate them. 303 f of X1 – X7(No VY8) 1: To be determined by the output unction status No. Function Range Unit Default Type F17.37 Virtual Input Terminal Status VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 000 00000 × 0: Disabled 1:
Enabled F17.38 Virtual Output Terminal Status VY8 VY7 VY6 VY5 VY4 VY3 VY2 VY1 000 00000 × 0: Disabled 1: Enabled No. Function Range Unit F18.00 Output Frequency Display present output frequency. Range: 0.00 - Upper Limit Frequency ★ This parameter will be updated in real time only when inverter is in speed control mode. Hz F18.01 Set Frequency Display present set frequency. Range: 0.00 - Maximum Frequency F00.16 ★ This parameter will be updated in real time only when inverter is in speed control mode. Hz F18.02 Not Used F18.03 Estimated Feedback Frequency Used to display estimated feedback frequency when inverter is in SVC control mode. Range: 0.00 - Upper Limit Frequency Hz