sinee — 7.24 F28 Air Compressor Application

EM500 Open-Loop Vector Control Inverter User Manual the lower limit pressure value. When the absolute value of error is less than this range, the PID function stops. When the feedback reaches at the given value for the first time, the limit deviation starts to act, PID function stops, when beyond the range, the limit deviation fails and the PID restarts to work.

Disconnection detection value, when the feedback pressure is less than the set value of this function code, the program will start counting, until the time of F28.24 is up, will the system report E46 fault Through this function code, you can select oil temperature, motor temperature (supports a variety of sensors) and air pressure sensor. If an interface card is used, temperature sensor can be adopted with PT100 . As the interface card is detachable, when the air pressure sensor is connected to the 343 No. Function Range Unit Default Type Pressure limit F28.22 0.00~100.00 % 0.00 ● deviation No.

Function Range Unit Default Type Pressure F28.23 disconnection 0.00~ Maximum pressure range MPa 0.08 〇 detection threshold Pressure 0.0~6000.0, 0.0 :The Function is F28.24 disconnection s 0.0 ● Disabled detection Time No. Function Range Unit Default Type Ones Place:oil temperature sensor 0: General channel 1: Interface card Tens Place: motor sensor 0: General channel 1: PT100 F28.25 sensor selection 101 〇 2: KTY84-130/150 3: PTC130/150 hundreds place: Air pressure sensor 0: General channel 1: Interface card