sinee — 7.24 F28 Air Compressor Application

EM500 Open-Loop Vector Control Inverter User Manual interface cards, the machine assembly becomes more convenient. F28.27 Port corresponds to the gauge’s maximum range of F28.26 Early-warning Temperature: For storage in case of power failure only, without any function, can be used for upper computer. Warning Temperature When the feedback temperature is greater than this temperature, the system will report E47 failure. 344 No. Function Range Unit Default Type Maximum F28.26 60.0~160.0 ℃ 125.0 〇 temperature range 0: AI1 1: AI2 Temperature F28.27 2: AI3 1 〇 feedback selection 3: AI4 4: HDI Temperature F28.28 0.0~ Maximum temperature range ℃ 80.0 ● Digital given No.

F unction Range Unit Default Type E F28.29 T arly-warning emperature Temperature Digital setting~ Warning Temperature ℃ 105.0 ● F28.30 T Warning emperature Early-warning Temperature~ Maximum temperature range ℃ 110.0 ● No. Function Range Unit Default Type Temperature F28.31 proportional gain 0.00~100.00 5.00 ● GP Temperature F28.32 0.000~60.000, 0.000: No Integral s 10.000 ● integral time GTi Temperature F28.33 differential time 0.000~60.000 ms 0.000 ● GTd Temperature F28.34 integral action 0.00~100.00 % 100.00 ● range Temperature F28.35 0.00~100.00 % 100.00 ● Regulation Upper