EM500 Open-Loop Vector Control Inverter User Manual 361 Disconnection 2. The analog input terminals are damaged 2. Check whether the analog terminals can detect the analog input normally. 3. Check the external devices. E47 Oil Temperature Over-temperatu re Error 1. When an expansion card is used, the PT100 is disconnected or the line is disconnected. 2. When using an external sensor, the sensor is damaged or the analog input terminal is damaged 1. Check the sensor for abnormalities. 2. Check whether the analog terminals can detect the analog input normally. 3. Check the external devices. E48 Oil Temperature Feedback Disconnection 1. The sensor is abnormal. 2. Input terminal is damaged. 1.
Check the sensor for abnormalities. 2. Check whether the analog terminals can detect the analog input normally. 3. Check the external devices. E49 Motor Over-temperatu re Error 1. When an expansion card is used, the PT100 is disconnected or the line is disconnected. 2. When using an external sensor, the sensor is damaged or the analog input terminal is damaged. 3. The temperature does not fall below the fault temperature of 25 degrees. 1. Check the sensor for abnormalities. 2. Check whether the analog terminals can detect the analog input normally. 3. Check the external devices. 4. The temperature dropped to -25 degrees below F28.44 setpoint temperature after fault .
E50 Motor Temperature Feedback Disconnection Error 1. The sensor is abnormal. 2. Input terminal is damaged. 1. Check the sensor for abnormalities. 2. Check whether the analog terminals can detect the analog input normally.