sinee — 10.1 Routine Maintenance and Inspection of inverter

EM500 Open-Loop Vector Control Inverter User Manual 10. Maintenance and Inspection 10.1 Routine Maintenance and Inspection of inverter Changes of working environment of inverter, such as temperature, humidity, smog, dust and so on, as well as aging of the inner parts of inverter inner, may cause various faults of inverter. Therefore, routine inspection and regular maintenance should be performed during the process of storage and use.  Before using inverter, user shall check if the components are broken or the screws are loose during transportation.  While using inverter, user shall regularly clean the dust and check whether the screws are loosened.

 If inverter is left unused for a long term, user is recommended to power on inverter every half year during the storage. Every time, inverter shall be powered on for half an hour. This will prevent the electronic device from invalidation.  Keep inverter away from heavy humidity and metal particles. If necessary, put it When inverter is in normal running, please check the items below: in an electric cabinet or a small room with protective measures.  Whether motor has abnormal sound and vibration.  Whether inverter and motor are overheated abnormally.  Whether the ambient temperature is too high.  Whether output current value is normal.

 Whether the cooling fan of inverter runs normally. According to service conditions, clients shall regularly inspect inverter for clearing faults and potential safety hazards. Cut off the power supply before checking, and start checking after the keypad LED goes out. The items to be checked are shown in Table 10-1. 369