sinee — 23.3.3.50x06 Write single register or command

EM500 Open-Loop Vector Control Inverter User Manual  Incorrect PDU  Sub-Function Code 0000: return the data transmitted in the request field in response. All messages should be request messages. The following is an example of requesting the remote device to return inquiry data. It uses sub-function code 0000. Using 2-byte data field (0xA537) to return data. 23.3.3.50x06 Write single register or command This function code is used to write single holding register in a remote device. Request PDU describes the address of the written register Normal response is a response to the request and returned after writing the register.

 Request PDU 389 Error Code 1 byte 0x88 Exceptional Code 1 byte See Table 12-4 Sub-Function Indication Data Field Data Field (Request) (Request) 0000 Return Inquiry Any Copy the request data Data … Request Response Field Name (0x) Field Name (0x) Field Name (0x) (normal) (abnormal) Function 08 Function 08 Function 88 Sub-Function Code 00 Sub-Function 00 03 Hi Code Hi Exceptional Sub-Function Code 00 Sub-Function 00 Code Lo Code Lo Data Hi A5 Data Hi A5 Data Lo 37 Data Lo 37 Function Code 1 byte 0x06 Register Address 2 bytes 0x0000 - 0xFFFF Register Value 2 bytes 0x0000 - 0xFFFF