EM500 Open-Loop Vector Control Inverter User Manual 13.3 Protocol Format 13.3.1 Standard frame format A frame header is used to indicate the beginning of a data frame or remote frame, as a definite dominant bit. In the standard format data frame, the identifier (CAN-ID) is composed of 11 bits, which is used to indicate the determined message to be transmitted. Its value is also the priority of the message to be transmitted. After the identifier is a remote transmission request bit, used to distinguish between data frames and remote frames, when the bit is dominant, that the transmission of data frames, as recessive, said the transmission of remote frames.
The control segment (DLC) consists of 6 bits, including reserved bits r1, r0, and 4-bit 412 Baud rate Maximum Baud rate Maximum length length of the of the bus bus 1Mbit/s 25m 125 kbit/s 500m 800 kbit/s 50m 50 kbit/s 1000m 500 kbit/s 100m 20 kbit/s 2500m 250 kbit/s 250m 10 kbit/s 5000m