sinee — 13.5 Abnormal information response

EM500 Open-Loop Vector Control Inverter User Manual 13.3.3 Register Address Distribution As same as MODBUS communication protocol register address, See details12.3.4 13.4 Broadcast messages The EM500 CANSinee protocol supports broadcast transmission of packets. The address of the CAN-ID node that defines the broadcast message is 0, and the slave device does not respond to the packet after receiving the broadcast message. The application of broadcast message is multi-machine synchronization. That is, multiple inverters are connected to the same network through CAN bus. One of them is used as a host to broadcast commands or parameter values (such as operating frequency) to the network.

Synchronous operation. 13.5 Abnormal information response When the master device sends a request to the slave device, the master station wants to 420 request Response Domain Domain Domain (hexadecimal (hexadeci Name (hexadecimal Name Name ) mal) (Abnorma ) (normal) l) CAN-ID 701 CAN-ID 77F CAN-ID 7FF Date 02 Date 04 Date 02 Length Length Length Date Hi 55 Slave 01 Slave address 01 address Date Lo AA Abnormal 00 Abnormal code 05 code Date Hi 55 Date Lo AA