sinee — 7.2 F01 Group: Motor 1 Parameter

EM600 High-Performance Vector Control Inverter User Manual R1 L1-Lm R2 L2-Lm I1 I2 U1 (1-s)/s*R2 I0 Lm Figure 7–6 Induction Motor Stable Equivalent Model In the figure, R1, L1, R2, L2, Lm and I0 refer to stator resistor, stator inductance, rotor resistor, rotor inductance, stator & rotor mutual inductance, and idling excitation current respectively. The field weakening factor of induction motor will be automatically set in motor parameter autotuning. Generally speaking, user does not set these factors.

134 Function Name of Function Parameter Description Unit Default Property Code Code F01.14 Induction Motor Field Weakening Factor 1 10.00 - 100.00 % 87.00 〇 F01.15 Induction Motor Field Weakening Factor 2 10.00 - 100.00 % 80.00 〇 F01.16 Induction Motor Field Weakening Factor 3 10.00 - 100.00 % 75.00 〇 F01.17 Induction Motor Field Weakening Factor 4 10.00 - 100.00 % 72.00 〇 F01.18 Induction Motor Field Weakening Factor 5 10.00 - 100.00 % 70.00 〇 Function Name of Function Parameter Description Unit Default Property Code Code F01.19 Stator Resistor of Synchronous Motor 1 - 60000 (Motor Rated Power ≤ 75kW) 0.1 - 6000.0 (Motor Rated Power >75kW) mΩ 〇 F01.20 d-Shaft Inductance of Induction Motor 0.01 - 600.00 (Motor Rated Power ≤ 75kW) 0.001 - 60.000 (Motor Rated Power >75kW) mH Up To Specific Model 〇 F01.21 q-Shaft Inductance of Synchronous Motor 0.01 - 600.00 (Motor Rated Power ≤ 75kW) 0.001 – 60.000 (Motor Rated Power >75kW) mH Up To Specific Model 〇 F01.22 Back Electromotive Force of Synchronous Motor 0.0 - 2000.0 (Back Electromotive Force of Rated Rotation Speed) V Up To Specific Model 〇 F01.23 Initial Electric Angle of Synchronous Motor 0.0 - 359.9 (Synchronous motor enabled) 〇