sinee — 7.2 F01 Group: Motor 1 Parameter

EM600 High-Performance Vector Control Inverter User Manual F01.09 - F01.13 are parameters of synchronous motor. However, user can not get these parameters generally. Please autotune motor parameters by F01.34. User must set parameters of F01.00 - F01.08 as per actual applications before motor parameter autotuning and make sure to select a proper type of motor (F01.00=2). EM600 inverter supports multiple types of encoders. Different encoders shall be equipped with different PG cards, so please select a correct PG card (refer to Appendix II). After installation, set F01.24 correctly according to specific applications, otherwise inverter may run normally.

When inverter is in FVC control mode, user must set encoder line number correctly, otherwise motor will not run normally. This parameter mainly applies to synchronous motor and can be set correctly by motor parameter autotuning. For an encoder with AB signal (F01.24=0/1), if PG feedback frequency and set frequency are found with opposite directions during debugging, set F01.27 as 1 when F01.27 = 0 and set F01.27 as 0 when F01.27 = 1. This parameter can be set correctly by motor parameter autotuning.

For an encoder with UVW signal (F01.24=0/3), if PG feedback frequency and set frequency are found with opposite directions during debugging, set F01.28 as 1 when F01.28 = 0 and set F01.28 as 0 when F01.28 = 1. 135 Function Name of Function Parameter Description Unit Default Property Code Code F01.24 Encoder Type 0: ABZ Incremental Encoder 1: UVW Incremental Encoder 2: UVW Wire-Saving Encoder 3: Not Used 4:

Rotary Transformer 0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F01.25 Encoder Resolution 1 - 65535 1024 〇 Fuction Name of Function Parameter Description Unit Default Property Code Code F01.26 Phase Angle of Zero Pulse of Encoder 0.0 - 359.9° 0.0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F01.27 AB Pulse Phase Sequence 0: Forward 1: Reverse 0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F01.28 Phase Sequence of UVW Encoder 0: Forward 1: Reverse 0 〇 F01.29 UVW Initial Offset Phase Angle 0.0 - 359.9° 0.0 〇