sinee — 7.2 F01 Group: Motor 1 Parameter

EM600 High-Performance Vector Control Inverter User Manual This parameter mainly applies to synchronous motor and can be set correctly by motor parameter autotuning. The rotary transformer has certain number of pole-pairs. While using this encoder, the parameters for pole-pairs must be set correctly. F01.31=0: Disabled Speed feedback disconnection protection function does not work. F01.31=1: Enabled When detecting feedback disconnection, inverter will report an encoder fault (22) after reaching the time set through F01.32. F01.33 refers to filter time of speed feedback. There is no need to adjust it generally and default applies. F01.34=0: No Autotuning F01.34=1 :

Induction motor remains stationary in parameter autotuning. User must set motor type (F01.00) and motor nameplate parameters (F01.01 - F01.08) correctly before stationary autotuning of induction motor. By stationary autotuning, user may can relevant parameters of induction motor, including F01.09 - F01.13. This method mainly applies to application where motor can not rotate, but its effect is not as good as that of rotational autotuning. F01.34=2 : Induction motor remains rotational in parameter autotuning. Please release the load.

136 Function Name of Function Code Parameter Description Unit Default Property Code F01.30 Rotary Transformer Pole-Pairs 1 - 65535 1 〇 Function Name of Function Code Parameter Description Unit Default Property Code F01.32 Speed Feedback Disconnection Detection Time 0.0 - 10.0 (0.0: Speed Feedback Disconnection Detection Disabled) 0.0 〇 F01.33 Filter Time of Speed Feedback 0.000 - 0.100 s 0.002 〇 Function Name of Function Parameter Description Unit Default Property Code Code F01.34 Motor Parameter Autotuning 0: No Autotuning 1: Stationary Autotuning of Induction Motor 2: Rotational Autotuning of Induction Motor 3: Not Used 11: Stationary Autotuning of Synchronous Motor 12:

Rotational Autotuning of Synchronous Motor 13: Autotuning of Encoder of Synchronous Motor 0 〇