sinee — 7.2 F01 Group: Motor 1 Parameter

EM600 High-Performance Vector Control Inverter User Manual User must set motor type (F01.00) and motor nameplate parameters (F01.01 - F01.08) correctly before rotational autotuning of induction motor. By rotational autotuning, user can get relevant parameters of induction motor, including F01.09 - F01.13. This method mainly applies to application where motor can rotate, but better not to have a load or better to have a light load in parameter autotuning, otherwise autotuning effect will go down. F01.34=3: Not Used. Synchronous motor has three autotuning methods. User may select one according to different applications.

However, user must autotune parameters for a newly installed or replaced motor. In VF control mode, user can only perform “12: Rotational Autotuning” or “11: Stationary Autotuning”, and input “Back Electromotive Force” (F01.22) manually; in FVC control mode, user can only perform “13: Autotuning of Encoder”; to further enhance control performance, user also needs to perform “12: Rotational Autotuning”. F01.34=11 : Synchronous motor remains stationary in parameter autotuning. User must set motor type (F01.00) and motor nameplate parameters (F01.01 - F01.05) correctly before stationary autotuning of synchronous motor.

By stationary autotuning, user may can relevant parameters of induction motor (F01.19 - F01.21), current loop parameters (F06.12 - F06.15), etc. This method mainly applies to application where motor can not rotate and user needs to input “Back Electromotive Force” (F01.22) manually. F01.34=2 : Synchronous motor remains rotational in parameter autotuning. User must set motor type (F01.00) and motor nameplate parameters (F01.01 - F01.05) correctly before rotational autotuning of synchronous motor.

By rotational autotuning, user may can relevant parameters of synchronous motor (F01.19 - F01.21), current loop parameters (F06.12 - F06.15), back electromotive force of synchronous motor (F01.22), etc. This method mainly applies to application where motor can rotate, but better not to have a load or better to have a light load in parameter autotuning, otherwise autotuning effect will go down. F01.34=13: Motor rotates slowly in encoder autotuning of synchronous motor. User must set motor type (F01.00), motor nameplate parameters (F01.01 - F01.05), encoder type (F01.24) and encoder line number (F01.25) correctly before encoder autotuning of synchronous motor.

For a rotary encoder, user must set the pole-pairs (F01.30). By encoder autotuning, user may can relevant parameters of synchronous motor (F01.19 - F01.21), encoder parameters (F01.26 - F01.29) and current loop parameters (F06.12 - F06.15). 1. Motor parameter autotuning is only enabled when inverter is in ENTER , after F01.34 is set as a corresponding value and RUN is pressed for confirmation. After parameter autotuning, inverter will set F01.34 as 0 automatically. 2. Make sure to autotune parameters before inverter starts to run in keypad start/stop control mode (F00.02=0): Motor parameter autotuning will start only by pressing FVC control, so as to achieve better control effect. 3.

Please extend acceleration/deceleration time and try autotuning again, in case an overcurrent or overvoltage fault occurs during autotuning. 4. User must set encoder type (F01.24), encoder line number (F01.25) and pole-pairs of rotatory voltage (F01.30, required when F01.24=4) 137