EM600 High-Performance Vector Control Inverter User Manual before autotuning of inverter with an encoder. Phase parameters (F01.27 - F01.28) can be set manually or obtained by autotuning. 5. Motor parameters of the first group above are only taken as an example. For motor parameters of the second group, please refer to those parameters of the first group. 7.3 F02 Group: Input Terminal Parameter EM600 inverter has 7 multi-functional input terminals (X1 - X7) and 3 analog quantity input terminals (AI1 - AI3, only enabled when corresponding function is the numeric input; refer to F02.31).
In addition, user may select an IO expansion card (EC-IO-A1), which offers 4 multi-function numeric input terminals (X8 - X11) and 1 analog quantity voltage signal input terminal (AI4, with the same setting as AI1 - AI3). X1 - X11 and AI1 - AI4 are 15 numeric multi-function input terminals. By setting function codes F02.00 - F02.14, user can define the functions of those input terminals respectively. For example, if F02.00=1, X1 is “RUN”. If terminal control (F00.02=1) is selected as command source, then inverter starts function RUN when X1 terminal input is valid. See Table 7–2 for specific function options.
Table 7–4 Numeric Multi-Function Input Terminals 138 Function Parameter Name of Function Code Unit Default Property Code Description F02.00 X1 Numeric Input Function See Table 7–4 Functions of Numeric Multi-Function Input Terminals 1 〇 F02.01 X2 Numeric Input Function 2 〇 F02.02 X3 Numeric Input Function 11 〇 F02.03 X4 Numeric Input Function 12 〇 F02.04 X5 Numeric Input Function 13 〇 F02.05 X6 Numeric Input Function 14 〇 F02.06 X7 Numeric Input Function 10 〇 F02.07 AI1 Numeric Input Function 0 〇 F02.08 AI2 Numeric Input Function 0 〇 F02.09 AI3 Numeric Input Function 0 〇 F02.10 AI4 Numeric Input Function (Expansion Card) 0 〇 F02.11 X8 Numeric Input Function (Expansion Card) 0 〇 F02.12 X9 Numeric Input Function (Expansion Card) 0 〇 F02.13 X10 Numeric Input Function (Expansion Card) 0 〇 F02.14 X11 Numeric Input Function (Expansion Card) 0 〇 Set Function Description Value 0 No Function Set “0:
No Function” for an unused or fault terminal to prevent false output.