EM600 High-Performance Vector Control Inverter User Manual Ie, Inverter Rated Current (F12.21) Ue, Inverter Rated Voltage (F12.20) Pe, Inverter Rated Power (F12.19) Output physical quantity of analog output terminal can be switched through DIP between voltage signal 0.00V - 10.00 V and current signal 0.00mA - 20.00mA. For voltage signal, 0.0% - 100.0% corresponds to output 0.00V - 10.00 V; for current signal, 0.0% - 100.0% corresponds to 0.00mA - 20.00mA. See 3.3.7 Analog Output Terminal Wiring.
These function codes are used to correct zero shift and output amplitude deviation of analog output generally, and they can be also used to define desired AO output curve to meet different instrument or other requirements. If use “b” for offset, “k” for gain, “Y” for actual output, and “X” for standard output, then actual output is: Y=kX + b. 1. In order to meet the requirements of various instruments or peripherals, full-scale voltage of M1 and M2 is 10.9V actually and full-scale current is 22mA actually. 2. Default settings of M1 and M2 are 0.00 - 10.00 V. 3. Please use a multimeter to test idling output of terminals M1 and M2, if there is high requirement on the accuracy of analog output.
7.5 F04 Group: Start/Stop Control Parameter F04.00=0: Start Directly Inverter starts with DC brake (not available if F04.04=0), conducts pre-excitation (not available if F04.07=0), starts at start frequency, and enters set frequency running after retention time of start frequency. F04.00=1: Rotation Speed Tracking Start Inverter will first perform rotation speed tracking (size and direction) at startup, and start up smoothly from actual rotation frequency of present motor. Set appropriate start frequency, in order to guarantee motor torque at start. In order to enable motor to make magnetic flux fully, it’s required to maintain motor’s start frequency for certain time.
Start frequency F04.01 is not limited by lower limit frequency. 157 Function Code Name of Function Code Parameter Description Unit Default Property F03.27 M1 Output Offset -100.0 - 100.0 % 0.0 ● F03.28 M1 Output Gain -10.00 - 10.00 1.00 ● F03.29 M2 Output Offset -100.0 - 100.0 % 0.0 ● F03.30 M2 Output Gain -10.00 - 10.00 1.00 ● Function Name of Function Parameter Description Unit Default Property Code Code F04.00 Start Mode 0: Start Directly 1: Rotation Speed Tracking Start 0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F04.01 Start Frequency 0.00 - 10.00 Hz 0.00 〇 F04.02 Start Frequency Retention time 0.00 - 60.00, Disabled at 0.00 s 0.00 〇