sinee — 7.5 F04 Group: Start/Stop Control Parameter

EM600 High-Performance Vector Control Inverter User Manual damaging motor; if magnetic flux brake is disabled, deceleration time will be long, but output current is small. As for start mode after fault or coast to stop, the default is the start as per setting of F04.00 (F04.26=0), but user may select torque tracking start (F04.26=1) in a fixed way. For various stop modes, see function code F04.00. F04.27=0 : Not to Confirm If running terminal (RUN or F/R) is on and F00.03 is set as 0 or 1, inverter is powered on while enabling or disabling terminal, or inverter runs directly while start/stop mode is switched to terminal. F04.27=1 :

Confirm Close running terminal, set F00.03 as 0 or 1, inverter cannot run directly when start or stop by terminal at power-on or when the starting or stop mode is switched to terminal mode. When the output frequency is below zero speed frequency, "zero speed" Terminal effective. If zero servo function is enabled when output frequency is lower than zero servo start frequency, inverter will enter zero servo running mode. When present motor is a synchronous motor (eg: F01.00=2) and in VF control, initial angle is crucial to the control performance; especially, motor may reverse at the moment of start.

Therefore, default of inverter is to perform initial position search after power-on or fault, so as to obtain better control performance. 162 Function Name of Function Parameter Description Unit Default Property Code Code F04.26 Start Mode after Fault/Coast to Stop 0: Start as per the Set Mode of F04.00 1: Rotation Speed Tracking Start 0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F04.27 Terminal Start Command Reconfirmation 0: Not to Confirm 1:

Confirm 0 〇 Function Name of Function Parameter Description Unit Default Property Code Code F04.29 Zero Frequency 0.00 - 5.00 Hz 0.25 ● Function Name of Function Parameter Description Unit Default Property Code Code F04.30 Initial Position Search after Power-on or Fault 0: Disabled 1: Enabled 0 ● Function Name of Function Parameter Description Unit Default Property Code Code F04.30 Initial Position Search after Power-on or Fault 0: Disabled 1: Enabled 1 ●