EM600 High-Performance Vector Control Inverter User Manual For mater-slave communication (F10.05=1) and the inverter is slave (F10.06=0) the torque limit is 700FH (communication setting) * 250% * F10.08 (gain). The range of 700FH is 0.00% to 100.00%. See Table 12-2 for details. For general communication (F10.05=0) the torque limit is 7019H * F06.10/F06.11. The range of 7019H is 0.0 to 250%. See Table 12-2 for details. F06.09=6 : Maximum of AI2 and AI3 (pencentage)* F06.10/F06.11 F06.09=7 : Minimum of AI2 and AI3 (pencentage)* F06.10/F06.11 1. This code indicates the ratio between output torque at torque limit and inverter rated output torque. 2.
User can set upper limit of torque as per actual demands to protect motor or meet the operating mode requirements. 3. The jog mode and the brake mode shall be set separately. Parameters of Current loop PID adjuster would directly impact the performance and stability of the system. On general applications, user does not need to change these When inverter is at the zero frequency running stage in SVC control mode (eg: F00.01=1), inverter acts as per setting of F06.17. If F06.17=0 , inverter performs the band-type brake as pe rset current of F06.18 to realize zero servo function. F06.17=1, Not to Process. F06.17=2, inverter will be blocked for output and coast to stop.
170 Function Name of Function Code Parameter Description Unit Default Property Code F06.12 Excitation Current Proportional Gain ACR-P1 0.00 - 100.00 0.50 ● F06.13 Excitation Current Integral Time Constant ACR-T1 0.00 - 600.00 0.00: No Integral ms 10.00 ● F06.14 Torque Current Proportional Gain ACR-P2 0.00 - 100.00 0.50 ● F06.15 Torque Current Integral Time Constant ACR-T2 0.00 - 600.00 0.00: No Integral ms 10.00 ● Function Name of Function Parameter Description Unit Default Property Code Code F06.17 SVC Zero Frequency Processing Method 0: Brake 1: Normal 2: No Output 2 〇 F06.18 SVC Zero Frequency Band-Type Brake Current 50.0 - 400.0 (100.0=Idling Current) % 100.0 〇