sinee — 7.7 F06 Group: Vector Control Parameter

EM600 High-Performance Vector Control Inverter User Manual User may adjust autotuning effect by this parameter when inverter is in initial position autotuning. The value of this parameter is usually got by autotuning and user does not need to set it manually. The higher the injection voltage is, the better autotuning effect will be. High frequency current injection method realizes detection of initial position of rotor.

When inverter is in stationary status, inject high frequency current to motor stator winding so as to estimate motor rotor position accurately by taking advantage of saliency effect and magnetic flux saturation characteristics and detecting the time of high frequency current peak. According to experimental result, this method does not have a high accuracy or depend upon any motor parameter.

Injection Current F06.29 F06.33 0 F06.28 F06.32 Frequency Figure 7-23 High Frequency Injection 172 Function Name of Function Parameter Description Unit Default Property Code Code F06.28 Injection Current at Frequency of Low Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 10.00 ● F06.29 Injection Current at Low Frequency Range 0.0 - 60.0 (100.0= Motor Rated Current) % 20.0 ● F06.30 Low Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F06.31 Integral Time of Low Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ● F06.32 Injection Current at Frequency of High Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 20.00 ● F06.33 Injection Current at High Frequency Range 0.0 - 30.0 (100.0= Motor Rated Current) % 8.0 ● F06.34 High Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F06.35 Integral Time of High Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ● Low低 F频req段uency Range High F 高req频uen段c y Range Lo w低 F频req段ue ncy